Thứ Hai, 24 tháng 8, 2026

Bearing concept for cables stayed bridge


OptionMain characteristicMost suitable span arrangementRemarks
1. Fixed bearing at one end of the girderRestrains longitudinal displacement at one end2–3-span bridges, small to medium scaleSimple, but large longitudinal forces may be transferred to the abutment/pier
2. Elastomeric bearing at one end of the girderAllows deformation while providing longitudinal stiffness2–3-span bridges, where restraint forces need to be reducedIntermediate solution between fixed and free/sliding bearings
3. Fixed bearing at a low-level positionProvides longitudinal restraint near the lower/central part of the structural system3-span bridges, particularly when centralized displacement control is desiredSuitable for controlling global longitudinal deformation
4. Elastomeric bearing at a low-level positionProvides restraint without fully locking longitudinal movement3-span and multi-span bridgesRelatively flexible with respect to temperature, shrinkage, and creep
5. Fixed bearing at one towerProvides direct longitudinal restraint at a tower3-span or multi-span bridges, with relatively stiff towersReduces longitudinal displacement but may induce large forces in the tower
6. Sliding bearings at all locationsNo rigid longitudinal restraint pointLong, multi-span bridges with significant thermal movementAnother mechanism is required to provide overall longitudinal stability
7. Free-floating bearing systemThe girder is essentially free to move longitudinally with structural deformationLarge cable-stayed bridges with very long main spansSignificantly reduces forces caused by temperature, shrinkage, and creep
8. Free-floating system + elastic restraint/damper at a low-level positionFree longitudinal movement combined with damping/restraintLong-span cable-stayed bridges subject to significant dynamic effectsOne of the more interesting configurations for long-span bridges
9. Elastomeric bearings at all locationsAll supports provide longitudinal stiffnessMulti-span bridges requiring distributed longitudinal-force sharingProvides better displacement control than a free-floating system
10. Fixed anchorage outside the towersLongitudinal restraint is provided outside the tower system2–3-span bridges or special bridge configurationsCan transfer longitudinal forces outside the main tower region
Phương ánĐặc điểmSơ đồ nhịp phù hợp nhấtNhận xét
1. Gối cố định tại một đầu dầmKhóa chuyển vị dọc tại một đầuCầu 2–3 nhịp, quy mô nhỏ–trung bìnhĐơn giản, nhưng lực dọc truyền vào mố/trụ lớn
2. Gối đàn hồi tại một đầu dầmCho phép biến dạng nhưng có độ cứng dọcCầu 2–3 nhịp, cần giảm lực khóaTrung gian giữa cố định và di động
3. Gối cố định tại vị trí thấpKhóa dọc tại vùng thấp/giữa sơ đồCầu 3 nhịp, đặc biệt khi muốn giữ tâm chuyển vịPhù hợp khi cần kiểm soát biến dạng toàn cầu
4. Gối đàn hồi tại vị trí thấpKhống chế nhưng không khóa hoàn toàn3 nhịp và nhiều nhịpKhá linh hoạt với nhiệt độ, co ngót, từ biến
5. Gối cố định tại một thápKhóa dọc trực tiếp tại thápCầu 3 nhịp hoặc nhiều nhịp, tháp tương đối cứngGiảm chuyển vị dọc nhưng có thể tạo lực lớn trong tháp
6. Gối di động tại tất cả các vị tríKhông có điểm khóa dọc cứngCầu dài, nhiều nhịp, biến dạng nhiệt lớnPhải có cơ chế khác để ổn định theo phương dọc
7. Gối bồng bềnh (free-floating)Dầm gần như "trôi" theo biến dạngCầu dây văng lớn, nhịp chính rất dàiGiảm mạnh lực do nhiệt/co ngót/từ biến
8. Bồng bềnh + cản đàn hồi tại vị trí thấpFree-floating nhưng có damping/restraintCầu dây văng dài, chịu động lực lớnMột trong các phương án đáng chú ý nhất
9. Gối đàn hồi tại tất cả vị tríCác điểm tựa đều có độ cứng dọcCầu nhiều nhịp, yêu cầu phân phối lựcKiểm soát chuyển vị tốt hơn free-floating
10. Neo cố định phía ngoàiKhống chế dọc ở ngoài hệ thápCầu 2–3 nhịp hoặc cầu đặc biệtCó thể đưa lực dọc ra ngoài vùng tháp
Main span (Nhịp chính


Xu hướng bố trí
< 150 m                                                Fixed / Elastic
150–250 m                                                Fixed / Elastic tại một vị trí
250–400 m                                                Elastic / Fixed tại tháp / nhiều gối đàn hồi
400–600 m                                                Elastic / Free-floating / Damper
    > 600 m                      Free-floating + damper hoặc hệ kiểm soát chuyển vị đặc biệt

Thứ Năm, 20 tháng 8, 2026

cái đẹp aashto

 



Mindmap thiết kế Cầu theo AASHTO

                          ┌──────────────────┐

                         │   BRIDGE NEED TO DESIGN │

                         └────────┬─────────┘

                                  │

                    ┌─────────────▼─────────────┐

                    │       LOAD MAP             │

                    │ DC DW LL WS TU TG PS ...  │

                    └─────────────┬─────────────┘

                                  │

                    ┌─────────────▼─────────────┐

                    │   LOAD COMBINATIONS        │

                    └─────────────┬─────────────┘

                                  │

             ┌────────────────────┼────────────────────┐

             │                    │                    │

         STRENGTH              SERVICE            EXTREME

             │                    │                    │

      ┌──────┼──────┐       ┌─────┼─────┐        ┌────┼────┐

      │      │      │       │     │     │        │    │    │

     VEHICLE     WIND    DC      Stress Crack Fatigue EQ Blast Collision

      │      │      │       │     │

     I,II  III,V   IV      I,II  III,IV

      │      │      │       │     │

      └──────┴──────┴───────┴─────┴──────────────┐

                                                  │

                                      GOVERNING MECHANISM

                                                  │

                            ┌─────────────────────┼──────────────────┐

                            │                     │                  │

                         STRENGTH              SERVICE            STABILITY

                            │                     │                  │

                         M,V,N,T             Stress/Crack        P-Δ/Buckling

                            │                     │                  │

                            └─────────────────────┼──────────────────┘

                                                  │

                                       DESIGN DECISION

                                                  │

                    ┌─────────────────────────────┼────────────────────────┐

                    │                             │                        │

                MATERIAL                    GEOMETRY                 STRUCTURAL SYSTEM

                    │                             │                        │

                 f'c, Fy                       h, b, t                  span

                 DUL                           section                  pier

                 rebar                         tendon                  box/girder

                    │                             │                        │

                    └─────────────────────────────┼────────────────────────┘

                                                  │

                                           OPTIMIZATION

                                                  │

                                     COST / WEIGHT / CONSTRUCTION

                                                  │

                                                  ▼

                                             FINAL DESIGN

Thứ Sáu, 7 tháng 8, 2026

Giỗ Bố Mẹ 2026

 Năm nay tổ chức giỗ vào ngày kỷ niệm 18 năm mẹ mất và 19 năm Bố đi xa. 25/7/ 2007-2008-:-2026 về ngày 25/7 đưa Tí em và Quỳnh về. Chiều trở về nhà.

Đám giỗ trang nghiêm ấm cúng. Con cháu đọc kinh tưởng nhớ các ngài, sau đó cùng chung vui bên mâm cơm. 

Chủ Nhật, 26 tháng 7, 2026

lấy lại đất cho nhà tổ 2025 - 2026

1. ngày ../3/2025 về xé bỏ tờ đo dạc đất để làm bản đồ số 

2. 27/7/2025 cắm lại mốc ngoài đường 

3. làm giấy trình ubnd xã về việc lấn ranh đất 

4. 9/10/2025 hòa giải lần đầu và xác định đúng ranh đất và mốc đất

5. 23/12/2025 ấp + tuyên qua cắm ngược lại qua đất 15cm không dựa trên 1 căn cứ pháp lý nào 

6. 3/2026 địa chính xã vào đo đạc và kết luân 2 bên tranh chấp 15cm

7. 28/4/2026 xử vụ mương nước - bên kia thua kiện và phải trả lại cho gia đình mình 40 tr

8. 22/7/2026 hòa giải ranh đất lần 2, xã tuyên bố vẫn căn cứ vào QSD đất + bb hòa giải lần trước, và không có sự thay đổi nào. nghiêng về phía nhà mình. 

hoàn toàn thắng đến xã, 

ông Huân không đồng ý, xã đề nghị bên kia đưa vụ việc ra tòa.

9. 27/7/2026 làm đơn đề nghị thanh tra, kiểm tra thủ tục và trình tự thực hiện việc chuyển nhượng từ Tiến qua Tuyên






Thứ Năm, 7 tháng 5, 2026

28 tháng 4 năm 2026

Sau nhiều ngày đấu tranh vất vả với hàng xóm, chúng tôi đã cùng xã giải quyết vụ việc hệ thống mương nước chung trong sạch sẽ.

Đã phải trả lại số tiền phần của nhà mình trong 5 hộ. 

Bài học rất quý giá cho việc đấu tranh đòi lại sự thật.

Mai sau chỉ dạy lại cho con cháu. 



Mindmap of Cable Stayed Bridge design